Biomolecular Interactions Service Lab

 

In the Biomolecular Interaction Laboratory we characterize the interaction of biomolecules using Biacore-3000 instrument, MicroCal iTC200, Monolith NT.115 and NT.LabelFree equipments. In addition, we have a Prometheus NT.48 device for the analysis of protein stability and heat denaturation. These devices are suitable for quantitative determination of binding constants as well as kinetic and thermodynamic characteristics.

Equipments

Biacore 3000

  • Surface Plasmon Resononance based binding technique
  • interaction analysis with immobilized ligand
  • integrated microfluidic system
  • different sensor chips available
  • the kinetics of interaction (ka és kd)
  • the affinity of interactions (KA=ka/kd or KD=kd/ka)
  • thermodynamics (∆G, ∆H, ∆S)
  • specificity of interactions (identification of interacting regions)
  • identification of interacting partners from lysates

Biacore

ITC MicroCal200

  • ligand in syringe (Injected into sample cell)
  • protein target in sample cell
  • heat release or intake of interaction is measured
  • hastelloy cell
  • cell volume: 200 μL
  • sensitive
  • multiple feedback modes
  • affinity KD from the millimolar (mM) to nanomolar (nM) range
  • number of binding sites (N)
  • thermodynamics: binding enthalpy (ΔH) and entropy (ΔS)

Instruments – Keck Biophysics Facility

 

 

 

 

 

 

 

Monolith NT.115

  • low sample volume (capillary volume ~6-8 μL)
  • quantifying the interactions of purified proteins or in complex bioliquids
  • Amine-reactive, cysteine-reactive or His-tag specific labeling using NanoTemper Protein Labeling Kits
  • affinity (KD)

monolith 115

Monolith NT.LabelFree

  • low sample volume (capillary volume ~6-8 μL)
  • without protein labelling (one interacting partner contains intrinsic fluorofores)
  • affinity (KD)

NTLF

Prometheus NT.48

  • protein heat stability screening (melting point TM)
  • from 15°C to 95°C
  • heating rate: 0.1 to 7°C/min
  • measure 48 capillaries „on-the-fly“ with in 3 seconds
  • low sample volume (capillary volume ~8-10 μL)
  • High-Resolution Biophysical Characterization
  • multi-domain unfolding transitions
  • antibodies + antibody drug conjugates
  • quality control
  • forced degradation
  • long-term stability of biologicals

Prometeus

Contact: erdodi@med.unideb.hu

                    bbalint@med.unideb.hu

 

The following charges are applied for the services

Work

Unit

Price (HUF)

Biacore-3000

Equipment usage time 

hour

10 000

Immobilization

1 chip/4 surfaces

15 000

Data evaluation            

1 concentration series  

18 000

 

 (min. 3, max 7 conc.)

Evaulation time  

hour

5 000

MicroCal ITC200

Equipment usage time

hour

10 000

Data evaluation

1 ligand titration with 1 interacting partner

5 000

Monolith NT.115 and NT.LabelFree

Equipment usage time

hour

10 000

Standard Capillaries

16 pieces per measurement

2 600

Premium Capillaries

16 pieces per measurement

11 500

Capillaries Monolith NT.LabelFree

16 pieces per measurement

7 800

Premium Capillaries Monolith NT.LabelFree

16 pieces per measurement

13 500

Protein labelling

per protein

35 000

Data evaluation

hour

5 000

Prometheus NT.48

Equipment usage time

hour

10 000

Standard Capillaries

3 pieces of per sample

750

High Sensitivity Capillaries

3 pieces of per sample

2 700

Data evaluation

hour

5 000

 

 